| Line 5: | Line 5: | ||
| * [[# | * [[# | ||
| * [[# | * [[# | ||
| - | * [[#Debug console]] | ||
| * [[# | * [[# | ||
| Line 20: | Line 19: | ||
| ===== Debugging test generation ===== | ===== Debugging test generation ===== | ||
| + | Debugging issues with test generation will require knowledge on the sequencer used. If you need a refreshing course on the sequencer works, check out [[../ | ||
| + | |||
| + | The first thing that you need is to identify the sequencer being used and the error message that may be displayed. | ||
| + | |||
| + | The sequencer used is shown on application toolbar on the upper-left corner of the IDE. Make sure that the expected sequencer has been chosen. | ||
| + | |||
| + | ==== Missing transitions ==== | ||
| + | In order for the sequencers to be able to generate test sequences from the model, the following conditions must hold true for all models: | ||
| + | * there must be a path from initial state to every state in the model | ||
| + | * there must be a path from every state to a final state | ||
| + | |||
| + | One of the common issues encountered during test generation is caused by missing transitions. An example model of such case is: | ||
| + | {{wiki: | ||
| + | |||
| + | As you may have picked up the error in the model - it breaks the first condition: there isn't a path from initial state " | ||
| + | | ||
| + | |||
| + | ==== Transition guards not working ==== | ||
| + | Another commonly encountered issue with test generation is the use of transition guard. | ||
| + | |||
| + | |||
| + | ==== Test case too long ==== | ||
| + | A test cases is represented as a path from the initial state to a final state. | ||
| + | |||
| + | If you wish to get a set of shorter test cases, you may choose // | ||
| + | |||
| + | |||
| + | |||
| + | |||
| ===== Debugging automation script ===== | ===== Debugging automation script ===== | ||
| - | ===== Debug console ===== | + | Automation scripts are called as model executes. If your automation script is not functioning as expected, you may try any of the following methods to trouble-shoot the problem: |
| + | * check //Server Log// file if receiving runtime errors | ||
| + | * add additional debugging messages and check //Script Log// file | ||
| + | * pause model and check if AUT is at the expected state | ||
| + | * dynamically execute scripts and validate the results | ||
| + | * highlight script and press // | ||
| + | * execute script in Debug Console in [[../ | ||
| + | |||
| + | |||
| ===== Logging ===== | ===== Logging ===== | ||
| + | |||
| + | // | ||
| + | |||
| + | You can also log messages from your scripts by using $SYS.log(...). | ||
| + | |||
| + | Some of the plugins may also creates driver specific log files, such as Selenium' | ||
| + | |||
| + | All log files can be found in //logs// folder. | ||